16
The eleventh day after successful docking.
At 2:47 a.m.,
the combined structure experienced an anomaly in its power bus voltage for the first time.
It was neither a power outage nor a short circuit, but an extremely regular, periodic voltage drop.
It occurred once every forty-seven seconds with a magnitude of about three percent, automatically recovering after 0.6 seconds.
It was as if a heartbeat had occasionally skipped a beat.
This was first discovered by the engineer on duty.
Frowning, he stared at the bus voltage curve on the monitoring screen, then pulled up historical data from the single-module operation period to compare.
During single-module operation, this curve had been completely straight.
"Report: after grid connection of the combined structure, there is a periodic slight dip in the bus voltage. The period is forty-seven seconds, with a magnitude of three percent."
The chief engineer immediately rushed over.
He took a look at the data, his first reaction being:
"Is it a stepping anomaly in the solar array drive assembly?"
"We've already ruled that out.
The operating parameters of the solar array drive assemblies on both modules are completely normal, and the stepping accuracy is within the allowable range."
"Mismatched parameters on the grid-tie controller?"
"We adjusted two sets of parameters, but it didn't help.
The drop period remains unchanged."
The chief designer fell silent for a moment, then asked the duty engineer to separately pull up the power generation curves of the two solar arrays and overlay them.
Two waveforms then appeared on the screen.
The output ripple frequency of the experimental module's solar array was... He narrowed his eyes.
Then he asked someone to pull up the ripple frequency of the docking module.
There was a difference of five-thousandths.
"There is a slight difference in the power generation ripple frequency between the two solar arrays."
The chief designer's voice deepened.
"Running them separately during ground tests was fine, but after grid connection..."
"When two power sources are connected in parallel, the frequency difference creates beat oscillations."
The power system engineer chimed in.
"It's like two singers singing the same pitch, but one is slightly off-key. Listening to them separately is fine, but together they produce a beat frequency."
"A difference of five-thousandths—why wasn't this detected on the ground?"
"Because during ground testing, we used solar array simulator power supplies from the same batch, with parameter consistency controlled within one-thousandth.
However, in actual space, the two solar arrays experienced different thermal cycling, micrometeoroid impacts, material aging, and so on."
"Manufacturing tolerances were amplified by space."
"Exactly."
...
At eight o'clock in the morning,
the chief designer reported the situation to Jiang Huaixing.
After listening to the report, Jiang Huaixing asked his first question.
"Is this oscillation currently affecting operations?"
"Not for now.
The three percent drop is within the allowable bus fluctuation margin.
However, long-term exposure will accelerate the aging of power converters.
Furthermore, if a third module is connected, the three frequency differences will superimpose, causing the oscillation to deteriorate exponentially."
"Correct."
Hearing this, Jiang Huaixing nodded and asked,
"How do we solve it?"
"On a hardware level, we could replace the grid-tie controller or install filtering devices.
However, we can't replace hardware in space."
"What about software?"
"If we can monitor the phase difference of the power generation ripples between the two arrays in real time, we can dynamically adjust the operating point of the solar array on one of the modules.
By having it slightly deviate from the optimal value of Maximum Power Point Tracking (MPPT),
we can artificially create a reverse ripple to cancel out the oscillation.
Theoretically, this is feasible."
"Theoretically?"
"Because we haven't verified it in space.
However, we've run similar schemes in ground simulations.
It's just that the ripple phase difference changes in real time in space, so the algorithm requires millisecond-level response times."
"Then do it."
Jiang Huaixing made the call.
"Run simulations on the ground first. Once we confirm the control logic is fine, uplink the commands."
Six hours after running the ground simulations,
the algorithm team fed in all the power generation data from the two solar arrays over the past eleven days, deducing the real-time variation pattern of the ripple phase difference.
They then designed a dynamic balancing algorithm.
They didn't need to strive for identical output from both arrays.
Instead, they allowed the docking module's solar array to make minor fluctuations on the MPPT curve—not exceeding two percent—to achieve an active shift in the ripple phase.
"Uplink commands ready."
The TT&C director confirmed.
"Wait a moment."
The chief engineer checked the time and said,
"Is the docking module currently in the sunlit zone or the shadow zone?"
"It will enter the shadow zone in three minutes and twenty seconds."
"Then wait until it enters the shadow zone before sending it.
Adjusting parameters while the solar arrays aren't generating power is safest and won't cause transient surges."
...
Three minutes and twenty seconds later, the uplink command was sent.
The operating point of the docking module's solar array began to fluctuate slightly.
On the ground monitoring system, the magnitude of the periodic drop on the bus voltage curve gradually narrowed—2.1%, 1.4%, 0.7%...
Then it disappeared.
The bus voltage flattened out again.
"Oscillation eliminated."
Relief radiated uncontrollably through the duty engineer's voice.
"Dynamic balancing has taken effect."
The chief engineer stared at the screen for a long time, then remarked:
"Software-defined spacecraft.
That used to be a slogan shouted by NASAN and ESAA, but now Xingkong Aerospace has actually made it run up in the sky."
Jiang Huaixing stood beside him without responding.
Looking at the voltage curve that had straightened out again, his mind was already contemplating the next problem.
Three modules, four modules... If the space station expands to six or eight modules in the future, how complex will the power network become?
This time, the two-module problem was solved via a dynamic balancing algorithm. But with more modules, frequency combinations become more complex, and beat oscillation patterns will evolve from a single period to multi-frequency superposition.
"Make this algorithm standard equipment for the next-generation power management system,"
he said to the power system engineer.
"It shouldn't just be an in-orbit patch—it needs to be built into the baseline design for all subsequent modules."
"Understood. However, beat suppression in multi-module scenarios will require new modeling."
"Then build it.
Space has provided us with a complete set of data this time.
So let's not waste it."
The following morning, word got out, sparking another wave of discussion.
However, the spread wasn't as massive as last time.
After all, ordinary people neither understood nor cared about things like a "minor bus voltage dip."
In industry circles, however, it caused a sensation.
A power system expert within the state establishment wrote a long post online:
"Beat oscillations after two-module grid connections are a classic dilemma in space station power system design.
The International Space Station encountered a similar issue during its early construction phase, solving it by installing hardware filters, which incurred significant weight and cost.
Xingkong Aerospace resolved this using software dynamic balancing. The approach is highly innovative and its effectiveness has been proven.
This demonstrates that their in-orbit software iteration capability has reached quite an advanced level.
From problem identification to resolution, it took under twelve hours."
Someone asked in the comments section, "Resolved in twelve hours?"
"Yes. Discovered in the early morning, resolved by morning."
"Xingkong Aerospace's efficiency is terrifying indeed."
"I don't think it's just terrifying efficiency, but rather a short decision-making chain.
Discover problem → analyze root cause → formulate solution → simulation verification → uplink command.
There are no layers of approval in between.
Many companies can't copy this speed.
Especially state teams—though they shouldn't copy it either.
After all, fault tolerance is different for crewed missions.
However, taking this path is right for commercial aerospace."
...