16
Friday of the third week.
Chen Fan
Chen Wen stood in the assembly room before a newly assembled S02 engineering prototype.
It featured a white casing with its arms hanging at its sides. The wrist interface cover plates were not yet installed, exposing the neat wire harness within.
"Is everything assembled?"
Jiang Huaixing walked in, followed by the Algorithm Group Leader and Xiao Zheng.
"Hardware assembly was completed last night. Today we're running system integration testing."
Chen Wen replied upon hearing this.
"We used the manufacturer's last original driver board, the reamers are Kuncheng samples, and the vibration sensors are mounted on the second revision of the differential board.
The software compensation parameters have also been entered."
He then pointed toward the adjacent test bench and asked,
"Mr. Jiang, shall we begin?"
Jiang Huaixing glanced over and nodded.
"Let's begin!"
The Algorithm Group Leader then stepped forward and connected his laptop to the prototype's debugging port.
A stream of startup logs scrolled across the screen.
Loading system kernel, initializing sensors, mounting NPU drivers, starting multimodal inference engine...
"All sensors are online."
Xiao Zheng reported, his eyes fixed on the monitoring panel.
"Vibration array six channels, IMU nine-axis, microphone four channels, vision module..."
When he reached the vision module, he paused.
At that moment, the Algorithm Group Leader spoke up.
"The vision module didn't come up."
The last line of the log halted at: 【ERROR】 Camera module init failed: I2C timeout
"Not again."
Chen Wen frowned.
"Last time, it was caused by poor ribbon cable contact, and replacing it solved the issue.
What happened this time?"
As he spoke, he crouched down to inspect the ribbon cable connecting the vision module to the motherboard.
The flexible FPC ribbon cable was plugged in properly, and the connector latch was firmly secured.
He unplugged it and reseated it, while someone on the Algorithm Group Leader's team restarted the vision driver.
Still a timeout.
"How about trying a different ribbon cable?"
Lao Zhao handed over a new FPC ribbon cable from the side.
Chen Wen took it, swapped it in immediately, and rebooted.
This time, the log changed to: 【WARN】 Camera module detected, resolution mismatch
"It's detected, but the resolution is wrong."
The Algorithm Group Leader pulled up the device tree configuration and said,
"The module reported 1080p, but the device tree is configured for 720p.
The previous development board used a 720p module, so after swapping to this new one on the prototype, it ran into trouble."
"Oh, right! The new batch of driver boards delivered by the manufacturer last week had an updated I2C device address table."
Chen Wen suddenly remembered and said,
"The new batch changed the vision module's I2C address from 0x3C to 0x3D, and the device tree wasn't updated accordingly."
"Does modifying the device tree require recompiling the kernel?"
"No, just modifying the device tree dtb file is enough.
I have the source code right here."
With that, Chen Wen opened his laptop and located the device tree source file.
He changed the camera node's I2C address from 0x3C to 0x3D, recompiled the dtb, and flashed it in.
After rebooting once again...
This time, the log read: 【INFO】 Camera module initialized: 1920x1080@30fps
"All set."
The Algorithm Group Leader said,
"Vision is up."
Jiang Huaixing stood nearby in silence, watching them resolve one startup issue after another.
It was not until 9:30, after starting at 8:00, that the prototype finally brought all of its sensors online.
The Algorithm Group Leader spoke up.
"Let's start running the full-link early warning test."
Saying so, he opened the test script, simulating a complete scenario sequence.
Beginning Step 1: Standby State.
In this state, the prototype's arms hung naturally, and while all sensors were fully active, the inference engine remained in low-power listening mode.
Then beginning Step 2: Triggered State.
In front of the test bench, Xiao Zheng pushed a fifty-centimeter-tall mannequin off the table, simulating a child falling from a height.
The vibration array responded immediately, with all six channels capturing the impact signal simultaneously, peaking at 0.41 g on the primary channel.
The acoustic spectrum matched a dull thud.
The IMU detected a free-fall phase of approximately 0.18 seconds.
The three signal paths completed joint assessment within eighty milliseconds.
The prototype raised both arms to execute a "contact emergency stop" action.
Its left arm then reached toward where the mannequin fell, while its right arm rose synchronously to form a protective posture.
The entire movement took only 0.42 seconds to complete.
"Red trigger, emergency stop response time: 420 milliseconds."
Xiao Zheng read out the data.
"Slightly slower than the 400 milliseconds required by specifications."
"420 milliseconds—off by twenty milliseconds."
The Algorithm Group Leader looked at Chen Wen and asked,
"Robotic arm response latency?"
"From receiving a command to actual movement, the joint module has a theoretical minimum latency of thirty-five milliseconds.
Plus NPU inference and communication overhead."
Chen Wen checked the log and said,
"NPU inference took fifty-two milliseconds, twelve milliseconds more than previously measured.
It's likely that once the vision module came online, it consumed system bus bandwidth, crowding out the inference engine's DMA channel."
"Can we raise the priority of the NPU's DMA channel?"
"Yes, modifying the bus arbitration parameters in the device tree will do it."
"Modify it. During the prototype demonstration, this latency cannot exceed 400."
Chen Wen immediately modified the bus priority configuration and ran the test again.
Second run: 403 milliseconds.
"Still over."
"We can't optimize it any further that way.
The hardware only has so much DMA bandwidth; running the vision module and the NPU simultaneously is bound to cause congestion."
The Algorithm Group Leader pondered for a moment, then said,
"The vision module doesn't actually need to run at full resolution under red trigger scenarios.
If we drop the vision to 480p and lower the frame rate from thirty to fifteen, we can cut bandwidth usage by seventy percent."
"However, the image will look blurry during the demo."
"There's actually no need to display high-definition feeds in real time.
When an alert is triggered, vision only serves as supplementary assessment; high resolution is reserved for manual retrospective review.
Low resolution is sufficient for real-time inference."
Chen Wen then adjusted the vision module's runtime parameters once more.
Third run.
This time, it took only 387 milliseconds.
"Passed."
The Algorithm Group Leader then proceeded with the remaining procedures.
Following a red trigger, the app should receive a push notification within two seconds.
He pulled out his phone.
At two seconds and forty milliseconds, the notification arrived.
A message popped up in the notification bar:
"Suspected fall detected. Risk level: High. Please verify child's status."
"App push notification is normal."
Next, they proceeded to Step 4: Orange Warning Test.
The Algorithm Group Leader had Xiao Zheng simulate an edge-case scenario.
A mannequin tilted slowly, sliding from a sitting position into a side-lying posture, without any impact peak or sound.
The vibration array captured a faint center-of-gravity shift signal of 0.09 g, well below the automatic trigger threshold.
The acoustic spectrum remained silent.
The IMU detected a gradual change in angular velocity.
The three-way joint assessment routed into the orange warning channel.
Concurrently, the LSTM temporal branch activated to analyze the duration and morphological changes of the motion sequence.
Instead of executing an emergency stop, the prototype adjusted its arms from hanging naturally to slightly bent, turning its head toward the incident.
"Orange warning does not trigger a physical emergency stop, but the posture adjustment signals that it has 'taken notice.'"
The Algorithm Group Leader explained,
"At the same time, the app pushes a lower-priority alert: 'Abnormal posture detected. Attention advised.'"
A second notification popped up on the phone.
Exactly three seconds.
...
Afterward, other functions were tested, and all were completed successfully.
"The full link has run through successfully."
Hearing this, Chen Wen finally breathed a sigh of relief.
...