16
At ten o'clock the next morning, the Algorithm Group Leader brought the test script and a debugging S02 engineering unit to the industrial park.
When he arrived, Chen Wen was already waiting for him in the temporary laboratory.
On the table in front of him lay three freshly sampled PCB boards.
They had green solder masks, and the components in the vibration sensor signal conditioning area were noticeably denser than before.
"We switched to the ADA4807, raising the gain from 20 dB to 34 dB."
Chen Wen flipped the board over to show him the back, saying,
"The layout was modified for the signal conditioning section, but everything else remains untouched.
For the first revision, we assembled two boards. I tested one last night, and the gain indeed went up."
"What about the noise floor?"
"Looking at the oscilloscope, the input short-circuit noise floor is lower than before.
Just as you said, the new op-amp has lower noise density. Even with the higher gain, the signal-to-noise ratio actually improved by about seven decibels."
The Algorithm Group Leader took the board and connected it to the debugging engineering unit.
He loaded the test sequence prepared last week, which contained 24-hour vibration sampling logs from seventeen households.
He intended to run the joint annotation framework again.
After completing the first run, he stared at the comparative data and remained silent for a few seconds.
Seeing this, Chen Wen asked,
"How is it?"
"The missed detection rate on soft surfaces dropped from twenty-four percent to eleven percent."
Hearing this, Chen Wen let out a whistle.
"And it's not just the missed detection rate."
The Algorithm Group Leader pulled up the detailed distribution and continued,
"Sixty percent of the missed samples below the 0.35 g threshold have now been recovered by the amplified signal.
Furthermore, those ambiguous events that were previously'stuck in the middle zone'—
whose vibration amplitudes ranged from 0.18 g to 0.28 g—
are all boosted above 0.25 g now, directly crossing the threshold to enter the auto-ingestion range."
As he spoke, he casually clicked open a specific sample.
This one, labeled H12, was the very first one that got stuck.
It was a video of a three-year-old child transitioning from crawling to sitting, with an impact of 0.18 g.
On the new board, after amplification of the same signal, the effective peak showed 0.27 g.
"From 0.18 to 0.27, it crossed the 0.25 threshold."
Chen Wen glanced at it and said,
"But this is normal activity, not a fall.
Won't the system trigger a false alarm?"
"No, it won't.
Although the vibration exceeded the threshold, the audio spectrum showed no anomalies, and the IMU detected no free-fall segment.
Since the other two channels in the joint decision weren't triggered, the confidence level was still classified as 'normal activity'.
The purpose of boosting the gain isn't to turn all signals into falls.
It's to make those weak signals, originally buried in the noise floor, 'visible' to the system, allowing the multi-channel joint decision process to properly classify them."
Immediately after, the Algorithm Group Leader pulled up another entry.
This was a video of a child slipping on a soft carpet.
Previously, the old board recorded an impact of 0.21 g, which was directly filtered out by the threshold.
Now, with the new board, it recorded 0.29 g.
The vibration crossed the threshold, the audio spectrum matched a thud sound, and the IMU detected a 0.12-second acceleration change.
With all three channels aligned, the confidence level was determined as'suspected fall', sending it directly into the manual verification pool.
"Look, this video was previously a missed detection,"
said the Algorithm Group Leader.
"And now, you see, it was picked right back up."
Chen Wen nodded and said,
"Looks like the results are even better than expected."
"There's still a problem, though."
The Algorithm Group Leader zoomed in on a detailed segment of the waveform.
About 0.5 seconds after the impact peak, a faint oscillation appeared.
Its magnitude was very small, only around 0.03 g, lasting for 0.2 seconds, and its shape didn't look like ground rebound.
Hearing this, Chen Wen leaned in closer to take a look.
"What is it?"
"It's coupled vibration generated by the movement of our robotic arm itself."
the Algorithm Group Leader said.
"Once the gain was boosted, sensor sensitivity increased. It not only amplified ground vibrations but also the structural vibration of the arm itself.
The impact signal of a child falling is fine, but if the robotic arm moves afterward—
such as turning or lifting—the internal structural vibrations of the arm will couple into the sensor.
That results in these small-amplitude oscillations."
"Will it interfere with the decision logic?"
"A single instance might not.
But if it happens consecutively in a short period—
for example, if the child falls and the robot immediately turns to respond, the coupled vibration from the arm movement and the ground's residual shocks could overlap, leading the system to misinterpret it as a second impact."
Chen Wen thought for a moment and said,
"Can we filter it out at the signal processing level?
After all, the vibration frequency of the robotic arm's movement should be different from a human body's impact."
"It can be separated in the frequency domain.
The main frequency of the arm's structural vibration is between 30 and 50 Hz, while human impact is between 8 and 15 Hz.
We just need to add a frequency-domain band-stop filter."
"Then let's add it."
Subsequently, the Algorithm Group Leader added a band-stop filter to the test script and re-ran the sequence.
The coupled oscillation was suppressed, while the ground impact signal remained unaffected.
"But this is only at the software level,"
Chen Wen continued.
"On the hardware side, if we can add vibration isolation at the sensor mount location to reduce coupling at the source, the result would be much cleaner."
"Can you modify that on your end?"
"The anti-vibration rubber pad was previously thinned down from 3 mm to 1.5 mm just to make space for the amplifier circuit.
Now that the gain issue is resolved, we can thicken the pad back, but what do we do about the amplifier circuit?"
The Algorithm Group Leader pondered and said,
"For the amplifier circuit, we could switch to an op-amp with a smaller package, or move part of the peripheral circuitry to the main board, leaving only the sensor and first-stage amplifier at the bottom of the arm."
"But the trace length from the bottom of the arm to the main board will increase. What about signal attenuation?"
"Use differential transmission.
The analog signal from the sensor is converted to differential first, routed to the main board, and then converted back to single-ended. Its noise immunity would be even stronger than it is now."
As he spoke, Chen Wen sketched a rough diagram on a notebook.
"Calculate it first.
If two traces won't fit, we'll switch to a digital sensor with direct I2S output, bypassing analog entirely."
"Is the sample rate of a digital sensor high enough?"
"Currently, we use a MEMS accelerometer with I2S output as an auxiliary sensor, while the primary vibration sensor is still an analog piezoelectric type.
If we want an all-digital solution, we'd have to replace the sensor body itself and go through selection again.
..."
As they talked, both of them paused at the same time.
It was that familiar endless loop again: changing A required moving B, moving B required changing C, and changing C looped right back to A.
"Let's leave it at that for now,"
Chen Wen set down his pen and said,
"we'll deploy the software band-stop filter first, and treat hardware vibration isolation as a next-generation optimization.
As long as the current version runs, it's fine."
"Alright.
Frequency-domain band-stop plus differential transmission—how long will it take your side to produce the second revision for these two items?"
"You can write the band-stop filter into the firmware today.
Differential transmission requires rerouting traces and a new layout, so five days at the earliest."
"Five days."
The Algorithm Group Leader pondered and said,
"Then I'll run the joint validation using single-ended traces first on my end, and align with you again when your second revision comes out."
"Works for me."
...
In the afternoon, the Algorithm Group Leader headed back.
Because he needed to synchronize the test data of the new board with his team.
Seeing the missed detection rate on soft surfaces drop from twenty-four percent to eleven percent,
Xiao Zheng clapped right at his desk and let out a cheer.
"Don't celebrate too early,"
said the Algorithm Group Leader.
"Running the complete dataset through the joint annotation framework will take another two days.
And..."
As he spoke, he pulled up the waveform record of the coupled vibration.
"Once the gain went up, the sensor started'seeing' more things.
It sees both what we need and what we don't need.
We need to add a new annotation rule: distinguish between ground impacts and structural vibrations caused by the robotic arm's own movement.
We'll also need an extra training session for the annotators."
Hearing this, the Data Team Leader noted it down.
Afterwards, the Algorithm Group Leader opened the training dashboard and fed the enhanced data collected from the new board into the model for incremental training.
With the LSTM temporal branch combined with the gain-boosted vibration signals, the overall accuracy of the joint confidence engine jumped up another notch.
He stared at the comprehensive metrics on the dashboard:
Single-channel vibration accuracy rose from 71% to 83%.
Three-channel joint accuracy rose from 89% to 94%.
Boundary sample confusion rate dropped from 5% to 3.7%.
Completely static and silent scenes also dropped from 18% to 12%.
It could be said that every metric was heading in a positive direction.
...
